Risk category
Suitable for patients at risk to very high risk.
Pressure ulcer categories
For the treatment of all categories of pressure ulcers, as part of a package of care.
Use within this product’s intended setting, fit and user-weight limits, following clinical assessment and the current Instructions for Use.
Pressure redistribution at the footboard
Repose Sole Protector is fitted to a bed’s footboard to provide an air support surface where the soles of the feet may contact it. It is secured to the footboard using its vertical and horizontal straps.
Choosing and fitting your support
Position at the foot end and secure the vertical straps around the footboard first, followed by the horizontal straps, using the supplied buckles. Check that it does not interfere with the bed or other equipment. This is a footboard support, not a wearable boot or a heel-offloading device.
Your selected configuration
| Supplied as | 1 sole protector with straps and 1 small pump |
|---|---|
| Quantity unit | One complete set |
| Dimensions | 860 × 370 mm (L × W). |
| User-weight guidance | No upper patient-weight limit is specified for the intended use. |
| Construction | TPU inflatable support with fixing straps. |
| Inflation | Manual inflation using the correct Repose pump and Smart Valve |
Each quantity you select is one complete supply configuration listed above.
Repose technology in daily use
Manual inflation with Smart Valve
The correct Repose pump sets the intended inflation pressure. Inflate with the user off the product. Use the pump specified for the supplied configuration.
See how it is fitted
Manufacturer demonstration for the Sole Protector family. Follow the current Instructions for Use. The model and optional items shown may differ from your selection; the included items listed on this page define your supply.
Daily checks and cleaning
Check inflation with the manufacturer’s daily squeeze check and inspect positioning and skin regularly. Reconnect the correct pump and top up within a maximum of 14 days; the daily check still applies between top-ups. Always inflate and top up with the person off the product.
Clean visible contamination with detergent, water and a non-abrasive cloth. In the absence of visible contamination, follow the manufacturer’s weekly cleaning guidance and local infection-control policy. Dry thoroughly. Do not machine wash, immerse or sterilise the inflatable support, and keep liquid out of the valve. Removable PU covers have separate washing instructions.
Clinical use and precautions
Keep the valve away from skin and avoid direct contact with open wounds or compromised skin. Seek clinical advice immediately if skin condition changes. Keep away from heat and sharp objects. The valve contains a metal spring: do not use near MRI equipment. Read the complete IFU before use.
Use as part of an assessed pressure-care plan, alongside appropriate skin checks, repositioning and other care. The support does not replace those measures.
Clinical information
These references provide clinical background for the wider Repose range. They are not trials of this Sole Protector, which is a footboard support rather than a wearable Foot Protector or heel-offloading device.
Clinical assessment, skin inspection, repositioning and the wider care plan remain essential. Use the current product instructions for indications, precautions and maintenance; older study protocols are not instructions for present-day use.
- A review of evidence for use of the Repose® product range
Samantha Holloway · 2015 · Wounds UK 11(4) · Narrative evidence review
Adult mattress-overlay and Foot Protector evidence review; broader Repose context, not a trial of every product configuration.
Original article / manufacturer reprint - Challenging the pressure sore paradigm
P. Price; S. Bale; R. Newcombe; K. Harding · 1999 · Journal of Wound Care 8(4):187–190 · Randomised comparative trial
Older adults with fractured neck of femur: mattress-overlay plus cushion support system; standard care continued.
Original article / manufacturer reprint - Two clinical evaluations of the Repose system
Ann MacFarlane; Sue Sayer · 2006 · Wounds UK 2(3):14–25 · Two clinical evaluations/audits
Separate adult Foot Protector and mattress-overlay evaluations in acute hospital settings.
Original article / manufacturer reprint
Explore the manufacturer’s clinical library of evidence
Some links above open the manufacturer’s summary of a paper, rather than its full text. Study type and product scope are shown with each reference.
Documents and practical guidance
Original manufacturer documents for this product family. Read the full instructions before use.
PDFInstructions for UseFull fitting, inflation, precautions and cleaning guidance.PDFPatient information leafletDaily checks and practical care information.PDFRecommended cleaning agentsManufacturer cleaning guidance; distinguish the air support from its cover.PDFRepose brochureProduct-family information and original manufacturer illustrations.PDFClinical library of evidenceStudies and evaluations for healthcare professionals; findings apply to the products and settings studied.Help with selection and fitting
For product, sizing or replacement-part enquiries, contact Prodromou Medical.
+357 22 337593 · info@prodromoumedical.com
| Brand | Repose |
| Supply Configuration | Product |
| Pack Format | Single |
| Pump Included | Small pump |