Risk category
Suitable for patients at risk to very high risk.
Pressure ulcer categories
For the treatment of all categories of pressure ulcers, as part of a package of care.
Use within this product’s intended setting, fit and user-weight limits, following clinical assessment and the current Instructions for Use.
Support the lower leg. Offload the heel.
Repose Foot Protector supports the lower leg so the heel can remain clear of the support surface. The air-filled device is used while the legs are elevated and is supplied here as a pair with one small manual pump.
Choosing and fitting your support
Measure from the base of the heel to the midpoint at the back of the knee while the person is seated. Check that the selected device fully supports the lower-leg size and shape. The Standard and Long options have different fitting ranges. Position the valves away from the skin, and confirm that the heels remain clear.
| Size | Knee-to-heel measurement | Inflated dimensions |
|---|---|---|
| Standard | 49–55 cm | 380 × 200 × 230 mm |
| Long | 55–69 cm | 510 × 200 × 330 mm |
Your selected configuration
| Supplied as | 1 pair of long foot protectors (2 protectors) and 1 small pump |
|---|---|
| Quantity unit | One pair and one pump |
| Leg measurement | 55–69 cm |
| Inflated dimensions | 510 × 200 × 330 mm |
| User-weight guidance | The manufacturer specifies no upper patient-weight limit for the intended use; correct fit and support remain essential. |
| Construction | Reactive air support in multi-directional stretch TPU. |
| Inflation | Manual inflation using the correct Repose pump and Smart Valve |
Each quantity you select is one complete supply configuration listed above.
Repose technology in daily use
Manual inflation with Smart Valve
The correct Repose pump sets the intended inflation pressure. Inflate with the user off the product. Use the pump specified for the supplied configuration.
See how it is fitted
Manufacturer demonstration. The guide covers both Foot Protector and Foot Protector PLUS. Use the Foot Protector section and Long fit guidance; this listing supplies a pair and one Small Pump. Follow the current product-specific Instructions for Use.
Daily checks and cleaning
Check inflation with the manufacturer’s daily squeeze check and inspect positioning and skin regularly. Reconnect the correct pump and top up within a maximum of 14 days; the daily check still applies between top-ups. Always inflate and top up with the person off the product.
Clean visible contamination with detergent, water and a non-abrasive cloth. In the absence of visible contamination, follow the manufacturer’s weekly cleaning guidance and local infection-control policy. Dry thoroughly. Do not machine wash, immerse or sterilise the inflatable support, and keep liquid out of the valve. Removable PU covers have separate washing instructions.
Clinical use and precautions
Use only with the legs elevated. Remove the protectors before walking. Do not use with the feet directly on the floor.
Keep the valve away from skin and avoid direct contact with open wounds or compromised skin. Seek clinical advice immediately if skin condition changes. Keep away from heat and sharp objects. The valve contains a metal spring: do not use near MRI equipment. Read the complete IFU before use.
Use as part of an assessed pressure-care plan, alongside appropriate skin checks, repositioning and other care. The support does not replace those measures.
Clinical information
Frontier links the following Foot Protector and Repose-range studies and evaluations. The device, patient group and care package differed between studies; findings should be read in that context and do not separately establish outcomes for every current size.
Clinical assessment, skin inspection, repositioning and the wider care plan remain essential. Use the current product instructions for indications, precautions and maintenance; older study protocols are not instructions for present-day use.
- A review of evidence for use of the Repose® product range
Samantha Holloway · 2015 · Wounds UK 11(4) · Narrative evidence review
Adult mattress-overlay and Foot Protector evidence review; broader Repose context, not a trial of every product configuration.
Original article / manufacturer reprint - Challenging the pressure sore paradigm
P. Price; S. Bale; R. Newcombe; K. Harding · 1999 · Journal of Wound Care 8(4):187–190 · Randomised comparative trial
Older adults with fractured neck of femur: mattress-overlay plus cushion support system; standard care continued.
Original article / manufacturer reprint - Pressure Ulcer Prevalence Audit: What are the benefits of doing it?
Anne Ballard Wilson · 2006 (manufacturer library date) · Hospital prevalence audit poster
Mixed hospital pressure-care provision and devices, comparing 2001 and 2006 audits.
Manufacturer clinical summary - Clinical Evaluation of the Effectiveness of a Multimodal Static Pressure Relieving Device
J. Osterbrink; H. Mayer; Gerhard Schröder · 2005 · Conference evaluation abstract
Repose system comprising overlay, cushion, Foot Protectors and Wedge; mixed hospital/nursing-home patients.
Original article / manufacturer reprint - Two clinical evaluations of the Repose system
Ann MacFarlane; Sue Sayer · 2006 · Wounds UK 2(3):14–25 · Two clinical evaluations/audits
Separate adult Foot Protector and mattress-overlay evaluations in acute hospital settings.
Original article / manufacturer reprint - Cost-effective pressure ulcer prevention: the paradigm shift?
Lynne Watret · 2007 · Nursing in Practice · Advertorial / practice discussion
Historical adult Repose care and economic context; not a new comparative trial.
Manufacturer clinical summary - Repose: The new pressure ulcer management paradigm?
Lynne Watret · 2007 · Wounds UK 3(4) · Advertorial / narrative literature discussion
Historical adult mattress-overlay care and economic discussion; not an independent clinical trial.
Manufacturer clinical summary - Recognising the feet as being at risk from pressure damage
Sue Bale; Patricia Price; Sally Rees-Mathews; Keith G. Harding · 2001 · British Journal of Nursing 10(20):1320–1326 · Survey followed by clinical audit
Adult Foot Protector and heel-support provision; does not establish the PLUS magnetic strap or Flex as the tested device.
Manufacturer clinical summary - Pressure Relief for Heels: An Effective Innovation
J. M. Melhuish; T. Bethaves; R. Williams; K. G. Harding · Undated · Laboratory volunteer investigation
Foot Protector interface-pressure/offloading investigation in four volunteers; not ulcer-healing outcomes.
Manufacturer clinical summary - Reduced heel pressure damage when using the Repose® Foot Protector
Julie Evans · 2009 · British Journal of Community Nursing 14(6), Wound Care supplement · Orthopaedic ward clinical evaluation
Adult Foot Protector alongside individualised pressure-ulcer prevention; not a PLUS/Flex-specific randomised trial.
Original article / manufacturer reprint - A long-term durability assessment of static air filled pressure redistribution devices in the community setting
Maria Poole; Anne Coghlan · 2008 (manufacturer library date) · Community loan-store durability evaluation
Durability/reuse observations for overlays, cushions and Foot Protectors; not a warranty or treatment trial.
Manufacturer clinical summary
Explore the manufacturer’s clinical library of evidence
Some links above open the manufacturer’s summary of a paper, rather than its full text. Study type and product scope are shown with each reference.
Documents and practical guidance
Original manufacturer documents for this product family. Read the full instructions before use.
PDFInstructions for UseFull fitting, inflation, precautions and cleaning guidance.PDFPatient information leafletDaily checks and practical care information.PDFRecommended cleaning agentsManufacturer cleaning guidance; distinguish the air support from its cover.PDFRepose brochureProduct-family information and original manufacturer illustrations.PDFClinical library of evidenceStudies and evaluations for healthcare professionals; findings apply to the products and settings studied.Help with selection and fitting
For product, sizing or replacement-part enquiries, contact Prodromou Medical.
+357 22 337593 · info@prodromoumedical.com
| Brand | Repose |
| Repose Size | Long |
| Supply Configuration | Product |
| Pack Format | Pair |
| Pump Included | Small pump |