Risk category
Suitable for patients at risk to very high risk.
Pressure ulcer categories
For the treatment of all categories of pressure ulcers, as part of a package of care.
Use within this product’s intended setting, fit and user-weight limits, following clinical assessment and the current Instructions for Use.
A wider overlay for a double bed
Repose Double provides a reactive air support surface for an appropriately sized double bed. It uses the same immersion and envelopment principle as the Repose overlay range, while maintaining a separate double-width configuration.
Choosing and fitting your support
Check the complete bed dimensions and the underlying mattress before fitting. Secure the overlay as shown in the Instructions for Use, and assess any side rails or other bed accessories. The user-weight guidance applies per person or side and depends on the underlying foam mattress.
The product gallery includes the manufacturer’s general mattress-overlay fitting demonstration. This set supplies one Double overlay and Small Pump; use its listed dimensions and included items. Follow the current product-specific Instructions for Use.
Your selected configuration
| Supplied as | 1 x Double Mattress overlay, 1 x small pump |
|---|---|
| Quantity unit | One complete set |
| User-weight guidance | Per person/side: 222 kg on a high-specification foam mattress; 139 kg on a non-high-specification foam mattress. |
| Construction | Reactive air support in multi-directional stretch TPU. |
| Inflation | Manual inflation using the correct Repose pump and Smart Valve |
Each quantity you select is one complete supply configuration listed above.
Repose technology in daily use
Manual inflation with Smart Valve
The correct Repose pump sets the intended inflation pressure. Inflate with the user off the product. Use the pump specified for the supplied configuration.
Clean, inspect and reuse
Repose can be cleaned and reused when the manufacturer’s cleaning and inspection instructions are followed. Check for damage and correct function before reuse.
Daily checks and cleaning
Check inflation with the manufacturer’s daily squeeze check and inspect positioning and skin regularly. Reconnect the correct pump and top up within a maximum of 14 days; the daily check still applies between top-ups. Always inflate and top up with the person off the product.
Clean visible contamination with detergent, water and a non-abrasive cloth. In the absence of visible contamination, follow the manufacturer’s weekly cleaning guidance and local infection-control policy. Dry thoroughly. Do not machine wash, immerse or sterilise the inflatable support, and keep liquid out of the valve. Removable PU covers have separate washing instructions.
Clinical use and precautions
The IFU excludes unstable spinal fractures, posture-management needs and body shapes that cannot be fully supported. Assess bed or trolley side rails with the complete support arrangement.
Keep the valve away from skin and avoid direct contact with open wounds or compromised skin. Seek clinical advice immediately if skin condition changes. Keep away from heat and sharp objects. The valve contains a metal spring: do not use near MRI equipment. Read the complete IFU before use.
Use as part of an assessed pressure-care plan, alongside appropriate skin checks, repositioning and other care. The support does not replace those measures.
Clinical information
Frontier links these Repose overlay and range studies and evaluations. Findings apply to the products, patient populations and care packages studied; they do not separately establish outcomes for every size or supply configuration.
Clinical assessment, skin inspection, repositioning and the wider care plan remain essential. Use the current product instructions for indications, precautions and maintenance; older study protocols are not instructions for present-day use.
- A multicentre prospective randomised controlled clinical trial comparing the effectiveness and cost of a static air mattress and alternating air pressure mattress to prevent pressure ulcers in nursing home residents
Dimitri Beeckman; Brecht Serraes; Charlotte Anrys; Hanne Van Tiggelen; Ann Van Hecke; Sofie Verhaeghe · 2019 · International Journal of Nursing Studies 97:105–113 · Multicentre randomised trial
Older high-risk Belgian nursing-home residents; a Repose support package over 14 days, not isolated product configuration effects.
Original article / manufacturer reprint - A review of evidence for use of the Repose® product range
Samantha Holloway · 2015 · Wounds UK 11(4) · Narrative evidence review
Adult mattress-overlay and Foot Protector evidence review; broader Repose context, not a trial of every product configuration.
Original article / manufacturer reprint - Pressure Relief With Visco-Elastic Foam or With Combined Static Air Overlay? A Prospective, Crossover Randomized Clinical Trial in a Dutch Nursing Home
Martin van Leen; Steven Hovius; Ruud Halfens; Jacques Neyens; Jos Schols · 2013 · Wounds 25(10):287–292 · Randomised crossover trial
Adult nursing-home prevention: static-air overlay on visco-elastic foam versus foam alone.
Original article / manufacturer reprint - Challenging the pressure sore paradigm
P. Price; S. Bale; R. Newcombe; K. Harding · 1999 · Journal of Wound Care 8(4):187–190 · Randomised comparative trial
Older adults with fractured neck of femur: mattress-overlay plus cushion support system; standard care continued.
Original article / manufacturer reprint - Pressure Ulcer Prevalence Audit: What are the benefits of doing it?
Anne Ballard Wilson · 2006 (manufacturer library date) · Hospital prevalence audit poster
Mixed hospital pressure-care provision and devices, comparing 2001 and 2006 audits.
Manufacturer clinical summary - Clinical Evaluation of the Effectiveness of a Multimodal Static Pressure Relieving Device
J. Osterbrink; H. Mayer; Gerhard Schröder · 2005 · Conference evaluation abstract
Repose system comprising overlay, cushion, Foot Protectors and Wedge; mixed hospital/nursing-home patients.
Original article / manufacturer reprint - Two clinical evaluations of the Repose system
Ann MacFarlane; Sue Sayer · 2006 · Wounds UK 2(3):14–25 · Two clinical evaluations/audits
Separate adult Foot Protector and mattress-overlay evaluations in acute hospital settings.
Original article / manufacturer reprint - Cost-effective pressure ulcer prevention: the paradigm shift?
Lynne Watret · 2007 · Nursing in Practice · Advertorial / practice discussion
Historical adult Repose care and economic context; not a new comparative trial.
Manufacturer clinical summary - Repose: The new pressure ulcer management paradigm?
Lynne Watret · 2007 · Wounds UK 3(4) · Advertorial / narrative literature discussion
Historical adult mattress-overlay care and economic discussion; not an independent clinical trial.
Manufacturer clinical summary - The use of a new overlay mattress in patients with chronic pain: impact on sleep and self-reported pain
P. Price; S. Rees-Mathews; N. Tebble; J. Camilleri · 2003 · Clinical Rehabilitation 17:488–492 · Prospective before/after study
Adult chronic-pain outpatients using an overlay; sleep and self-reported pain, not a neonatal or heel-device trial.
Original article / manufacturer reprint - Repose: the cost-effective solution for prompt discharge of patients
Sylvie Hampton · 2000 · British Journal of Nursing 9(21):2249–2253 · Product-focus / practice review
Adult overlay use and discharge planning; historical economic context.
Manufacturer clinical summary - A long-term durability assessment of static air filled pressure redistribution devices in the community setting
Maria Poole; Anne Coghlan · 2008 (manufacturer library date) · Community loan-store durability evaluation
Durability/reuse observations for overlays, cushions and Foot Protectors; not a warranty or treatment trial.
Manufacturer clinical summary
Explore the manufacturer’s clinical library of evidence
Some links above open the manufacturer’s summary of a paper, rather than its full text. Study type and product scope are shown with each reference.
Documents and practical guidance
Original manufacturer documents for this product family. Read the full instructions before use.
PDFInstructions for UseFull fitting, inflation, precautions and cleaning guidance.PDFPatient information leafletDaily checks and practical care information.PDFRecommended cleaning agentsManufacturer cleaning guidance; distinguish the air support from its cover.PDFRepose brochureProduct-family information and original manufacturer illustrations.PDFClinical library of evidenceStudies and evaluations for healthcare professionals; findings apply to the products and settings studied.Help with selection and fitting
For product, sizing or replacement-part enquiries, contact Prodromou Medical.
+357 22 337593 · info@prodromoumedical.com
| Brand | Repose |
| Repose Size | Double |
| Supply Configuration | Product |
| Pack Format | Single |
| Pump Included | Small pump |
Our latest content
Check out what's new in our company !